Tennis Court Lighting Photometric Data
Single Recreational & Residential Court
Home › Commercial Lighting › Sports & Athletic Field LIghting › Tennis Court Lighting › Tennis Court Lighting Photometric Data
Single Recreational & Residential CourtÂ
Summary
Lumen Rating: 107,800
Average: Â Â 60.91
Maximum: Â 84
Minimum: Â 48
Max/Min Ratio: Â 1.4
Initial foot candle levels at 3-foot above court. Fixtures are mounted at 22′ above court.
Dual Recreational & Residential Court
Summary
Lumen Rating: 107,800
Average: Â Â 66.4
Maximum: Â 105
Minimum: Â 49
Max/Min Ratio: Â 2.14
Initial foot candle levels at 3-foot above court. Fixtures are mounted at 22′ above court.
Single Tournament & Club CourtÂ
Summary
Lumen Rating: 107,800
Average: Â Â 70.73
Maximum: Â 87
Minimum: Â 56
Max/Min Ratio: Â 1.55
Initial foot candle levels at 3-foot above court. Fixtures are mounted at 22′ above court.
Summary
Lumen Rating: 107,800
Average: Â Â 77.09
Maximum: Â 109
Minimum: Â 57
Max/Min Ratio: Â 1.91
Initial foot candle levels at 3-foot above court. Fixtures are mounted at 22′ above court.
Dual Narrow Recreational & Residential CourtÂ
Summary
Lumen Rating: 107,800
Average: Â Â 61.67
Maximum: Â 103
Minimum: Â 46
Max/Min Ratio: Â 2.24
Initial foot candle levels at 3-foot above court. Fixtures are mounted at 22′ above court.
Dual Narrow Tournament & Club Court
Summary
Lumen Rating: 107,800
Average: Â Â 77.62
Maximum: Â 119
Minimum: Â 56
Max/Min Ratio: Â 2.13
Initial foot candle levels at 3-foot above court. Fixtures are mounted at 22′ above court.
| Recommended Illumination For Outdoor Tennis Facilities | ||||
| Performance Criteria |
Recommended |
Minimal |
||
| Excellent | Very Good | Good | Fair | |
| Average Maintained Horizontal Foot candles within PPA | 125 | 100-75 | 75-50 | 50-30 |
| Minimum Maintained Horizontal Foot candles within PPA | 100 | 100-60 | 60-40 | 40 |
| Maximum Uniformity Ratio | 1.50 | 1.70 | 2.00 | 2.50 |